1057 universal transmitter for water analysis

1057 universal transmitter for water analysis
Manufacturer:
ЭКОХИМПРИБОР

1057 transmitter has three inputs from sensors and four current outputs that allows to reduce consumption by one circuit and saves panel space.
Input board for pH signal supports pH, ORP measurements and measurements using ion selective electrodes (ISE).

Input board for conductivity signal supports measurement of conductivity and specific resistance, determination of total content of dissolved solids, salinity, as well as allows to plot a graph of percentage concentration for specific applications.

Thanks to modular structure, signal input boards can be replaced in field conditions that simplifies configuration changes. For convenience purposes, real-time measurement data are always shown on the display during adjustment and calibration.

Standard structural features includes insulated inputs, 7 in-built languages, four current outputs 4-20 mA, 4 signaling relays.

Analyzer has in-built preamplifier with SMART technology for electrochemical analog sensors.

More
Category: Transmitters and controllers for fluid analyzers

1057 transmitter has three inputs from sensors and four current outputs that allows to reduce consumption by one circuit and saves panel space.
Input board for pH signal supports pH, ORP measurements and measurements using ion selective electrodes (ISE).

Input board for conductivity signal supports measurement of conductivity and specific resistance, determination of total content of dissolved solids, salinity, as well as allows to plot a graph of percentage concentration for specific applications.

Thanks to modular structure, signal input boards can be replaced in field conditions that simplifies configuration changes. For convenience purposes, real-time measurement data are always shown on the display during adjustment and calibration.

Standard structural features includes insulated inputs, 7 in-built languages, four current outputs 4-20 mA, 4 signaling relays.

Analyzer has in-built preamplifier with SMART technology for electrochemical analog sensors.

Technological information and specifications of device

Casing material

Polycarbonate. NEMA 4X/CSA 4

Dust and moisture protection

IP65

Cable conduit openings 

It is possible to use ½ inch fitting or PG13.5.

Display 

Monochrome graphic LCD. Resolution: 128 x 96 pxl. Display backlight. Active display surface: 58 x 78 mm (2.3 x 3.0 inch).

Ambient temperature and humidity 

From 0 to 55 C, relative humidity from 5 to 95 % (without condensation).

Storage temperature

from -20 to 60°С

Power supply 

Optional

02

24 VDC and 4 relays

03

Switch-selectable AC 85-265VAC, 50/60 Hz, 4 signaling relays

Relay

With break-make contact (C type), single-pole double-throw (SPDT), impeded into epoxied resin.

Input

Up to three electrically insulated inputs of signals from sensors.

Output

Four electrically isolated current outputs 4-20 mA or 0-20 mA. Extensibility Maximum load: 550 Ohm

Accuracy of current output

± 0.05 mA at 25 °C

Camp connection specifications 

Power socket (3 outputs): 24-12 AWG wires. Connector blocks on signal board: 26-16 AWG wires. Power socket connectors (4 outputs): 24-16 AWG wires. Connector blocks on signal relay: 24-12 AWG wires.

Weight/shipping weight

(rounded to 0.5 kg): 1.5 /2.0 kg

Dimension 

155 x 155 x 131 mm

1057 transmitter has three inputs from sensors and four current outputs that allows to reduce consumption by one circuit and saves panel space.
Input board for pH signal supports pH, ORP measurements and measurements using ion selective electrodes (ISE).

Input board for conductivity signal supports measurement of conductivity and specific resistance, determination of total content of dissolved solids, salinity, as well as allows to plot a graph of percentage concentration for specific applications.

Thanks to modular structure, signal input boards can be replaced in field conditions that simplifies configuration changes. For convenience purposes, real-time measurement data are always shown on the display during adjustment and calibration.

Standard structural features includes insulated inputs, 7 in-built languages, four current outputs 4-20 mA, 4 signaling relays.

Analyzer has in-built preamplifier with SMART technology for electrochemical analog sensors.

Technological information and specifications of device

Casing material

Polycarbonate. NEMA 4X/CSA 4

Dust and moisture protection

IP65

Cable conduit openings 

It is possible to use ½ inch fitting or PG13.5.

Display 

Monochrome graphic LCD. Resolution: 128 x 96 pxl. Display backlight. Active display surface: 58 x 78 mm (2.3 x 3.0 inch).

Ambient temperature and humidity 

From 0 to 55 C, relative humidity from 5 to 95 % (without condensation).

Storage temperature

from -20 to 60°С

Power supply 

Optional

02

24 VDC and 4 relays

03

Switch-selectable AC 85-265VAC, 50/60 Hz, 4 signaling relays

Relay

With break-make contact (C type), single-pole double-throw (SPDT), impeded into epoxied resin.

Input

Up to three electrically insulated inputs of signals from sensors.

Output

Four electrically isolated current outputs 4-20 mA or 0-20 mA. Extensibility Maximum load: 550 Ohm

Accuracy of current output

± 0.05 mA at 25 °C

Camp connection specifications 

Power socket (3 outputs): 24-12 AWG wires. Connector blocks on signal board: 26-16 AWG wires. Power socket connectors (4 outputs): 24-16 AWG wires. Connector blocks on signal relay: 24-12 AWG wires.

Weight/shipping weight

(rounded to 0.5 kg): 1.5 /2.0 kg

Dimension 

155 x 155 x 131 mm

Our contacts
pin_drop
г. Москва, Бережковская набережная,16А стр.3
show on the map
schedule
пн-пт с 9 до 18
Отдел сервисного обслуживания
pin_drop
г. Дубна, ул. Университетская, д. 11, стр. 14
show on the map
schedule
пн-пт с 9 до 18
Отдел сервисного обслуживания

    Contact us