Gas analysis equipment

Siemens ULTRAMAT 23 Gas Analyzers

Siemens ULTRAMAT 23 Gas Analyzers

ULTRAMAT 23 gas analyzer is a cost effective device as it can be used for measurements of four gas components: О2, CO, NO and SO2 with a single device. The device is developed on the basis of emission with two- or three-layer detector ensuring high selectivity and accuracy of measurements. Automatic calibration by ambient air ensures long-term high stability of zero point and measurable value without expensive reference gas.

 

Siemens OXYMAT 6 and OXYMAT 61 Gas Analyzers

Siemens OXYMAT 6 and OXYMAT 61 Gas Analyzers

OXYMAT 6 is a gas analyzer based on paramagnetic method for high accuracy determination of oxygen concentration in gases. When two gases with various oxygen content combine in a magnetic field, a pressure difference occurs between them.

OXYMAT 61 – simplified version of oxygen gas analyzer for standard application fields.

OXYMAT 64 – high-sensitivity version of oxygen gas analyzer with minimum measurement range of 0 – 10 ppm.

OXYMAT 6 uses alternating pressure method, where the pressure difference between the measured and reference gas is used as a measurement value. Whereby fast-response micro-flow transducer located in the reference gas is used as a sensor. As a result, OXYMAT 6 has not movable components and measurement gas does not contact the components of measurement system ensuring extra long service life and high stability of the device.

Siemens CALOMAT 6 and CALOMAT 62 Gas Analyzers

Siemens CALOMAT 6 and CALOMAT 62 Gas Analyzers

CALOMAT 6 is a system of device for generator control. Calomat 6 gas analyzers are designed for determination of composition of two-component gas systems with measurable component: Нr, Не, Аr, CO2 in nitrogen and can be applied during production of pure gases in industrial process to determine the purity of applied gas.

CALOMAT 62 – is a modified version for control of one of the gases: H2, N2, Cl2, HCl or NH3.

Siemens LDS 6 and SITRANS SL Gas Analyzers

Siemens LDS 6 and SITRANS SL Gas Analyzers

LDS 6 and SITRANS SL gas analyzers — laser diode spectrometers. The devices are used for “In-Situ” determination of concentration in gases. Their operating principle is based on absorption spectroscopy in long wavelength infrared region where diode laser, applied as a source of light, correlates with the absorption spectral lines of the measured gas. Laser is in the central processor.

Siemens FIDAMAT 6 Gas Analyzers

Siemens FIDAMAT 6 Gas Analyzers

FIDAMAT 6 — gas analyzer with flame ionization detector for continuous measurement of total content of organic compounds (hydrocarbon and high-boiling gas mixtures) in air, aggressive and compressed gases. For the first approximation, measurement results are proportional to the number of carbon atoms in molecule.

Siemens ULTRAMAT 6 Gas Analyzers

Siemens ULTRAMAT 6 Gas Analyzers

ULTRAMAT 6 is a gas analyzer working on the principle of non-dispersive (without spectral decomposition) infrared (NDIR) spectrometry for determination of concentration of gases having selective absorption. ULTRAMAT 6 uses the principle of antiphase transmission of radiation, divided into two beams by gas-filled beam divider, through measuring cell filled with sample and reference cell filled with gas that does not absorb infrared radiation. One or two gases are measured with high level of selectivity, whereby absorption bands of such gases fall within the range of infrared wave-length from 2 to 9 µm, such as CO, CО2, NO, SО2, NH3, H2О, CH4 and other hydrocarbons.

Siemens ULTRAMAT / OXYMAT 6 Gas Analyzers

Siemens ULTRAMAT / OXYMAT 6 Gas Analyzers

Ultramat / Oxymat 6, Oxymat 61 gas analyzers are designed for measurement of volume ratio of carbon monoxide, carbon dioxide, sulfur dioxide, nitrogen oxide, nitrous oxide, ammonia, methane­, ethane, ethylene, acetylene, propane, butane, hexane and oxygen in non-explosive mixtures.

Gas analyzer application field: process control of gas environments in various­ industry areas.

Millenium II Gas Contamination Detector

Millenium II Gas Contamination Detector

Net Safety Millenium gas contamination detectors for working spaces are designed for measurement of toxic, fire hazardous substances in working zone air.

Modern, high-tech Millenium II controllers, as well as a set of sensors, allow to resolve a wide range of tasks related to safety assurance.

Depending on the task, it is possible to use either simple and cheap Millennium II Basiс controllers, or more complex universal Millenium II controllers.

WC-3000, Oxymitter 4000 and Oxymitter 5000 Oxygen Analysers

WC-3000, Oxymitter 4000 and Oxymitter 5000 Oxygen Analysers

WC-3000, Oxymitter 4000, Oxymitter 5000 oxygen analyzers are designed for measurement of oxygen concentration in fuel combustion­ effluent gases.

Analyzers can be applied for systems of combustion process control and optimization in heating boilers, burning kilns, and for refuse incineration.

WC-3000, Oxymitter 4000, Oxymitter 5000 oxygen analyzers are registered in the State Register of metering devices.

X-STREAM Gas Analyzers

X-STREAM Gas Analyzers

X-STREAM gas analyzers are designed for continuous determination of ammonia, argon, carbon monoxide, helium, hydrogen, methane, nitric oxide, oxygen, sulfur dioxide, water vapor, hexane, ethylene, butane, toluene content in industrial­ emissions, exhaust gases, and for determination of admixtures in pure gases.

Models XS-02, XGP, X2GP, XFD, X2FD, XF, X2F, X2FN, X2GC of X-STREAM gas analyzers are registered in the State Register of metering devices.

Gas analyzers can be applied in chemical, oil and gas, gas industries ­ and scientific studies.