CVU portable conductivity measurement system
Portable conductivity measurement module includes 1065 analyzer and at least one 404 sensor. Devices are fixed in a protective casing, connected and calibrated as per NIST standards. All necessary components are included into the delivery set. CVU-01 model includes 404-11-17 sensor made on stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards. CVU-02 model includes two 404-11-17 sensors made of stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards.
Portable conductivity measurement module includes 1065 analyzer and at least one 404 sensor. Devices are fixed in a protective casing, connected and calibrated as per NIST standards. All necessary components are included into the delivery set. CVU-01 model includes 404-11-17 sensor made on stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards. CVU-02 model includes two 404-11-17 sensors made of stainless steel with 0.01 constant cell size connected to 1056-01-20-38-AN analyzer securely fixed in the protective casing and calibrated as per NIST standards.
Technological information and specifications of 1056 analyzer |
|||
Casing material | Polycarbonate. NEMA 4X/CSA 4 | ||
Dust and moisture protection | IP65 | ||
Cable conduit openings | It is possible to use ½ inch fitting or PG13.5. | ||
Display | Monochrome graphic LCD. Resolution: 128 x 96 pxl. Display backlight. Active display surface: 58 x 78 mm (2.3 x 3.0 inch). | ||
Ambient temperature and humidity | From 0 to 55 C, relative humidity from 5 to 95 % (without condensation). | ||
Storage temperature | from -20 to 60 С | ||
Power supply and output signals | Optional | 01 | 115/230 VAC, 50/60 Hz without relay, not available for -27, -37 options |
02 | 24 VDC and 4 signaling relays | ||
03 | Switch-selectable AC 85-265VAC, 50/60 Hz, 4 signaling relays | ||
AN | 4-20 mA current output. | ||
DP | Profibus DP Digital Communication + 4-20мА | ||
HT | HART® Digital Communication + 4-20мА | ||
Input | One of two insulated sensor inputs. | ||
Accuracy of current output | ± 0.05 mA at 25 °C | ||
Camp connection specifications | Power socket (3 outputs): 24-12 AWG wires. Connector blocks on signal board: 26-16 AWG wires. Power socket connectors (4 outputs): 24-16 AWG wires. Connector blocks on signal relay: 24-12 AWG wires. | ||
Weight/shipping weight | (rounded to 0.5 kg): 1.5 /2.0 kg | ||
Dimension | 155 x 155 x 131 mm |
Technological information and specifications of 404 sensor |
|
Cell constant | 0.01/cm, 0.1/cm, |
Temperature interval | Option-17: 0-100ºC |
Pressure Max. | Option-17: 791 kPa (7.9 bar) |
Wetted materials | Option-17: Titanium, 303 stainless steel, PEEK, EPDM |