High temperature (HT) pH sensors PERpH-X manufactured by Rosemount Analytical have several structural innovations that increase lifespan of pH sensor in complex high-temperature processes. ACCUGLASS™ pH flask means that HT sensors have higher resistance to crackling and response time close to the theoretical one even at ultimate pH values. GPHT glass is resistant to destruction glass matrix in high-temperature processes that ensures exceptional thermal stability of pH glass membrane. Slotted tip around glass flask protects the flask from direct impact of hazardous factors and can be rotated up to 90 degrees for self-cleaning. HT PERpH-X sensors have improved dual coupled standard perfectly applicable in severe conditions. External standard on a gel basis preserves viscosity ensuring resistance to thinning temperature and pressure effects. Outflow of standard into the operating flow is controlled using porous teflon connection that can be replaced in case of pollution or clogging. Specially designed connection is chemically stable and has a large surface area to maintain stable reference signal when used in polluted or oil-contaminated conditions.

More
Category: Special sensors

High temperature (HT) pH sensors PERpH-X manufactured by Rosemount Analytical have several structural innovations that increase lifespan of pH sensor in complex high-temperature processes. ACCUGLASS™ pH flask means that HT sensors have higher resistance to crackling and response time close to the theoretical one even at ultimate pH values. GPHT glass is resistant to destruction glass matrix in high-temperature processes that ensures exceptional thermal stability of pH glass membrane. Slotted tip around glass flask protects the flask from direct impact of hazardous factors and can be rotated up to 90 degrees for self-cleaning. HT PERpH-X sensors have improved dual coupled standard perfectly applicable in severe conditions. External standard on a gel basis preserves viscosity ensuring resistance to thinning temperature and pressure effects. Outflow of standard into the operating flow is controlled using porous teflon connection that can be replaced in case of pollution or clogging. Specially designed connection is chemically stable and has a large surface area to maintain stable reference signal when used in polluted or oil-contaminated conditions.

Technological information and specifications

Characteristics

3300HT & 3300HTV

3400HT & 3400HTVP

3500HT & 3500HTVP 

Measurement range

from 0 to 14 pH

ORP from  -1500 to +1500 mV

Linearity percent in pH range 

pH range 

HT series 

0 – 2 pH

94%

2 – 12 pH

99%

12 – 13 pH

97%

13 – 14 pH

92%

Wetted materials

Titanium, Ryton™, Teflon®, glass and EPDM,

Gasket rings – optional Viton® or Kalrez®

Process connection

1” connector

1” connector

1 1/4” or 1 1/2” ball valve

1” MNPT thread on the front and rear parts of the sensor

Operating Temperature

Without preamplifier

from 5°C to 155°C

from 5° to 120°C

With SMART preamplifier

(3300HTVP and 3400HTVP models  option -70)

Up to 85°C

Up to 110°C

Storage temperature

From -10°C to 70°C

From -10°C to 70°C

From -10°C to 50°C

Maximum process pressure

1825 kPa (absolute) at (100°C)

1825 kPa (absolute) at (100°C)

790 kPa (absolute)

Maximum process pressure in case of extractable (cut-in) connection.

524 kPa (absolute) Code 21

343 kPa (absolute) Code 25

790 kPa (absolute) at 120°C

Conductivity

Over 100 µS/cm

Reference electrode

Dual reference electrode with exchangeable gel electrolyte and Teflon® connection.

In-built cable

Standard one piece 15 in.

PN 24281-00 cable for 3300VP/3400VP models

Option-01: 8.3 m ready-made cable

Option-01: 5 m ready-made cable

Optional:

9.5” cable

ONLY for 3400HT

Weight / shipping weight

0.5 kg/ 0.9 kg

Code 21

0.9 kg/1.4 kg

0.5 kg/ 0.1 kg

Code 25

1.4 kg/1.8 kg

High temperature (HT) pH sensors PERpH-X manufactured by Rosemount Analytical have several structural innovations that increase lifespan of pH sensor in complex high-temperature processes. ACCUGLASS™ pH flask means that HT sensors have higher resistance to crackling and response time close to the theoretical one even at ultimate pH values. GPHT glass is resistant to destruction glass matrix in high-temperature processes that ensures exceptional thermal stability of pH glass membrane. Slotted tip around glass flask protects the flask from direct impact of hazardous factors and can be rotated up to 90 degrees for self-cleaning. HT PERpH-X sensors have improved dual coupled standard perfectly applicable in severe conditions. External standard on a gel basis preserves viscosity ensuring resistance to thinning temperature and pressure effects. Outflow of standard into the operating flow is controlled using porous teflon connection that can be replaced in case of pollution or clogging. Specially designed connection is chemically stable and has a large surface area to maintain stable reference signal when used in polluted or oil-contaminated conditions.

Technological information and specifications

Characteristics

3300HT & 3300HTV

3400HT & 3400HTVP

3500HT & 3500HTVP 

Measurement range

from 0 to 14 pH

ORP from  -1500 to +1500 mV

Linearity percent in pH range 

pH range 

HT series 

0 – 2 pH

94%

2 – 12 pH

99%

12 – 13 pH

97%

13 – 14 pH

92%

Wetted materials

Titanium, Ryton™, Teflon®, glass and EPDM,

Gasket rings – optional Viton® or Kalrez®

Process connection

1” connector

1” connector

1 1/4” or 1 1/2” ball valve

1” MNPT thread on the front and rear parts of the sensor

Operating Temperature

Without preamplifier

from 5°C to 155°C

from 5° to 120°C

With SMART preamplifier

(3300HTVP and 3400HTVP models  option -70)

Up to 85°C

Up to 110°C

Storage temperature

From -10°C to 70°C

From -10°C to 70°C

From -10°C to 50°C

Maximum process pressure

1825 kPa (absolute) at (100°C)

1825 kPa (absolute) at (100°C)

790 kPa (absolute)

Maximum process pressure in case of extractable (cut-in) connection.

524 kPa (absolute) Code 21

343 kPa (absolute) Code 25

790 kPa (absolute) at 120°C

Conductivity

Over 100 µS/cm

Reference electrode

Dual reference electrode with exchangeable gel electrolyte and Teflon® connection.

In-built cable

Standard one piece 15 in.

PN 24281-00 cable for 3300VP/3400VP models

Option-01: 8.3 m ready-made cable

Option-01: 5 m ready-made cable

Optional:

9.5” cable

ONLY for 3400HT

Weight / shipping weight

0.5 kg/ 0.9 kg

Code 21

0.9 kg/1.4 kg

0.5 kg/ 0.1 kg

Code 25

1.4 kg/1.8 kg

Our contacts
pin_drop
г. Москва, Бережковская набережная,16А стр.3
schedule
пн-пт с 9 до 18
Отдел сервисного обслуживания
pin_drop
г. Дубна, ул. Университетская, д. 11, стр. 14
schedule
пн-пт с 9 до 18
Отдел сервисного обслуживания

г. Москва info@ecohimpribor.ru

г. Санкт-Петербург spb@ecohimpribor.ru

г. Краснодар krd@ecohimpribor.ru

г. Казань kzn@ecohimpribor.ru

г. Омск oms@ecohimpribor.ru

г. Новосибирск nsk@ecohimpribor.ru

г. Иркутск irk@ecohimpribor.ru

г. Пермь prm@ecohimpribor.ru

    Contact us